Products specific for Baltic
- Control cable 450/750 V
- Installation cable 300/500 V
- Installation cable 450/750 V
- Installation wire 450/750 V
- Power cable 0,6/1 (1.2) kV
- Power cable for ploughing 0,6/1 (1.2) kV
- Rising main 450/750 V
Products specific for Denmark
- Armeret installationskabel 450/750 V
- Installationskabel 300/500V
- Installationskabel 450/750 V
- Kraftkabel 0,6/1 (1.2) kV
- Renovations kabel 450/750 V
- Styrekabel 450/750 V
Products specific for Norway
- Brannalarmkabel 300/500 V
- Flyplasskabel 1,7/3 (3,6) kV
- Flyplasskabel 3,6/6 (7,2) kV
- Installasjonskabel 300/500 V
- Installasjonskabel 450/750 V
- Koblingsledning 300/500 V
- Koblingsledning 450/750 V
- Kraftkabel i aluminium 0,6/1 (1.2) kV
- Kraftkabel i kobber 0,6/1 (1.2) kV
- Signalkabel 300/500 V
- Signalkabel 450/750 V
- Stigekabel med 5 ledare 450/750 V
Products specific for UK
- Aluminium Power Cable 0,6/1 (1.2) kV
- Aluminium Power Cable 600/1000 V
- Auxliary Cable 600/1000 V
- Copper Power Cable 0,6/1 (1.2) kV
- Copper Power Cable 600/1000 V
- Instrumentation cable C 300/500 V
- Instrumentation cable IC 300/500 V
- Split Copper Power Cable 600/1000 V

Installation cable EKLK
450/750 V
SS 424 02 19-4
For fixed installations indoors and outdoors. Not to be laid directly in soil nor in cast concrete.
| Conductor |
Circular, solid copper |
| Fire class | F4C » |
| Insulation | PVC-compound |
| Filling material | Filling sheath |
| AL screen | Aluminium tape, Stranded copper coil tinned copper wires1 mm² |
| Sheath | Galvanized twofold steel tapes |
| Min.handling temperature ºC | -15 |
| Max. conductor temperature ºC | +70 |
| Conductor shortcircuit temperature 5 s ºC | +160 |
| These types are available also halogen free, as REKOCLEAN products |
| Product number | Size | Diameter [mm] | Weight [kg/km] | Maximum allowed bending radius in installation [cm] | Maximum allowed bending radius in final installation [cm] |
|---|---|---|---|---|---|
| 04 570 11 | 3G1,5 | 9.5 | 150 | 10 | 3 |
| 04 570 12 | 3G1,5 | 9.5 | 150 | 10 | 3 |
| 04 570 13 | 3G1,5 | 9.5 | 150 | 10 | 3 |
| 04 570 14 | 3G2,5 | 11 | 200 | 11 | 3 |
| 04 570 15 | 3G2,5 | 11 | 200 | 11 | 3 |
| 04 570 16 | 3G2,5 | 11 | 200 | 11 | 3 |
| 04 570 17 | 4G1,5 | 11 | 180 | 11 | 3 |
| 04 570 18 | 4G1,5 | 11 | 180 | 11 | 3 |
| 04 570 19 | 4G1,5 | 11 | 180 | 11 | 3 |
| 04 570 20 | 4G2,5 | 12 | 230 | 12 | 4 |
| 04 570 21 | 4G2,5 | 12 | 230 | 12 | 4 |
| 04 570 22 | 4G2,5 | 12 | 230 | 12 | 4 |
| 04 570 23 | 5G1,5 | 12 | 210 | 12 | 4 |
| 04 570 24 | 5G1,5 | 12 | 210 | 12 | 4 |
| 04 570 25 | 5G1,5 | 12 | 210 | 12 | 4 |
| 04 570 26 | 5G2,5 | 13 | 290 | 13 | 4 |
| 04 570 27 | 5G2,5 | 13 | 290 | 13 | 4 |
| 04 570 28 | 5G2,5 | 13 | 290 | 13 | 4 |
| Size | Maximum allowed pulling force when pulling from conductors [kN] | Maximum DC-resistance of phase conductor +20°C [ohm/km] | Packing [m] |
|---|---|---|---|
| 3G1,5 | 0.23 | 12.1 | 50 coil |
| 3G1,5 | 0.23 | 12.1 | 250 PK |
| 3G1,5 | 0.23 | 12.1 | 500 K5 |
| 3G2,5 | 0.38 | 7.41 | 50 coil |
| 3G2,5 | 0.38 | 7.41 | 150 PK |
| 3G2,5 | 0.38 | 7.41 | 500 K6 |
| 4G1,5 | 0.30 | 12.1 | 50 coil |
| 4G1,5 | 0.30 | 12.1 | 200 PK |
| 4G1,5 | 0.30 | 12.1 | 500 K6 |
| 4G2,5 | 0.50 | 7.41 | 50 coil |
| 4G2,5 | 0.50 | 7.41 | 150 PK |
| 4G2,5 | 0.50 | 7.41 | 500 K7 |
| 5G1,5 | 0.38 | 12.1 | 50 coil |
| 5G1,5 | 0.38 | 12.1 | 150 PK |
| 5G1,5 | 0.38 | 12.1 | 500 K7 |
| 5G2,5 | 0.63 | 7.41 | 50 coil |
| 5G2,5 | 0.63 | 7.41 | 150 PK |
| 5G2,5 | 0.63 | 7.41 | 500 K7 |
Reka Product Support Service
Reka Cables maintain this Product Support Service for use of customers of Reka Cables Ltd and customers of Reka Corporation. From the Service customers can load and obtain in e-form product – and support material for Reka Products for their own business needs. Reka Product Support Service can be used by all customers, who approve these conditions.
The use of Reka® trade mark and the material obtainable from the Product Support Service is limited to the normal conduct of business of customers and to connection thereof, but provided that that the use will not defame the Reka® trade mark and is not in conflict with good business manners. The right of use of use is free of charges and valid until further notice.
The customer is not allowed to convey the material loaded or printed from Reka Product Support Service, except in normal connection to business for purposes such as planning, advertising and the like or as attached to such material. The origin of the material must be mentioned in connection thereof.
Reka® trade mark and the material obtainable in e-form from Reka Product Support Service, as well as the copyrights related thereof, are property of Reka Cables Ltd and in connection with copying or printing these rights will not be conveyed of transferred to the customer even in part. Reka Cables Ltd guarantees that these materials, which can be printed or loaded from the site, do not infringe immaterial rights of third parties.
Reka Cables Ltd reserves the right to close the Product Support Service without prior notice and reserves the right to limit or prevent the use of the Product Support Service by certain identified users without prior notice.
The pages of Reka Product Support Service can be used in the form as they appear at each occasion. Reka Cables Ltd has done its best to ensure that the information is correct and up-to-date, but it can nor be guaranteed that the pages could not contain unintended mistakes or out-of-date information. Reka Cables Ltd underlines that technical information and price information on the pages is not binding.
Reka Cables Ltd is not liable for damages, which may result in relation with mistakes or incorrect information on the pages or files of Reka Product Service, malfunction of the pages or with use of information obtainable from the pages without separately confirming from Reka Cables Ltd that the information used is correct and up-to-date.