Products specific for Baltic
  • Rising main 450/750 V

Products specific for Denmark

  • Installationskabel 300/500V
  • Renovations kabel 450/750 V
  • Styrekabel 450/750 V

Products specific for Norway

  • Brannalarmkabel 300/500 V
  • Flyplasskabel 1,7/3 (3,6) kV
  • Flyplasskabel 3,6/6 (7,2) kV
  • Installasjonskabel 450/750 V
  • Koblingsledning 300/500 V
  • Koblingsledning 450/750 V
  • Signalkabel 300/500 V
  • Signalkabel 450/750 V
  • Stigekabel med 5 ledare 450/750 V

Products specific for UK

  • Aluminium Power Cable 0,6/1 (1.2) kV
  • Auxliary Cable 600/1000 V
  • Copper Power Cable 0,6/1 (1.2) kV
REKA kaapeli
reko

Installation wire MKEM 90

450/750 V
HD 21.7; HD 21.3

For fixed installation in conduit and for internal wiring of electrical devices.

Conductor Circular, fine stranded copper
Special property Maximum allowed continuous operating temperature of conductor 90º
Fire class F2 »
Insulation PVC-compound
Min.handling temperature ºC -15
Max. conductor temperature ºC +90
Conductor shortcircuit temperature 5 s ºC +160
These types are available also halogen free, as REKOCLEAN products
Product number Size Diameter [mm] Weight [kg/km] Maximum allowed bending radius in installation [cm] Maximum allowed bending radius in final installation [cm]
04 038 02 1,5 BR 3 20 2 1
04 038 03 1,5 BK 3 20 2 1
04 038 07 1,5 BU 3 20 2 1
04 038 08 1,5 YE/GN 3 20 2 1
04 038 23 2,5 BK 4 30 3 1
04 038 27 2,5 BU 4 30 3 1
04 038 28 2,5 YE/GN 4 30 3 1
04 038 43 4 BK 4.5 45 4 1
04 038 47 4 BU 4.5 45 4 1
04 038 48 4 YE/GN 4.5 45 4 1
04 038 63 6 BK 5 65 4 2
04 038 67 6 BU 5 65 4 2
04 038 68 6 YE/GN 5 65 4 2
04 038 83 10 BK 7 120 6 2
04 538 83 10 BK 7 120 6 2
04 038 87 10 BU 7 120 6 2
04 538 87 10 BU 7 120 6 2
04 038 88 10 YE/GN 7 120 6 2
04 538 88 10 YE/GN 7 120 6 2
04 039 03 16 BK 8 170 6 2
04 539 03 16 BK 8 170 6 2
04 039 07 16 BU 8 170 6 2
04 539 07 16 BU 8 170 6 2
04 039 08 16 YE/GN 8 170 6 2
04 539 08 16 YE/GN 8 170 6 2
04 039 13 25 BK 9.5 260 8 3
04 539 13 25 BK 9.5 260 8 3
04 039 17 25 BU 9.5 260 8 3
04 539 17 25 BU 9.5 260 8 3
04 039 18 25 YE/GN 9.5 260 8 3
04 539 18 25 YE/GN 9.5 260 8 3
04 039 23 35 BK 11 360 9 3
04 539 23 35 BK 11 360 9 3
04 039 27 35 BU 11 360 9 3
04 539 27 35 BU 11 360 9 3
04 039 28 35 YE/GN 11 360 9 3
04 539 28 35 YE/GN 11 360 9 3
04 039 33 50 BK 13 490 10 4
04 539 33 50 BK 13 490 10 4
04 039 37 50 BU 13 490 10 4
04 539 37 50 BU 13 490 10 4
04 039 38 50 YE/GN 13 490 10 4
04 539 38 50 YE/GN 13 490 10 4
04 039 43 70 BK 14 690 11 4
04 539 43 70 BK 14 690 11 4
04 039 47 70 BU 14 690 11 4
04 539 47 70 BU 14 690 11 4
04 039 48 70 YE/GN 14 690 11 4
04 539 48 70 YE/GN 14 690 11 4
04 039 53 95 BK 17 930 14 5
04 039 63 120 BK 19 1160 15 6
04 039 73 150 BK 21 1450 17 6
Size Maximum allowed pulling force when pulling from conductors [kN] Maximum DC-resistance of phase conductor +20°C [ohm/km] Packing [m]
1,5 BR 0.08 13.3 250 coil
1,5 BK 0.08 13.3 250 coil
1,5 BU 0.08 13.3 250 coil
1,5 YE/GN 0.08 13.3 250 coil
2,5 BK 1.25 7.98 200 coil
2,5 BU 1.25 7.98 200 coil
2,5 YE/GN 1.25 7.98 200 coil
4 BK 2.00 4.95 100 coil
4 BU 2.00 4.95 100 coil
4 YE/GN 2.00 4.95 100 coil
6 BK 3.00 3.30 100 coil
6 BU 3.00 3.30 100 coil
6 YE/GN 3.00 3.30 100 coil
10 BK 5.00 1.91 100 coil
10 BK 5.00 1.91 1000 K5
10 BU 5.00 1.91 100 coil
10 BU 5.00 1.91 1000 K5
10 YE/GN 5.00 1.91 100 coil
10 YE/GN 5.00 1.91 1000 K5
16 BK 0.80 1.21 100 coil
16 BK 0.80 1.21 1000 K6
16 BU 0.80 1.21 100 coil
16 BU 0.80 1.21 1000 K6
16 YE/GN 0.80 1.21 100 coil
16 YE/GN 0.80 1.21 1000 K6
25 BK 1.25 0.78 100 coil
25 BK 1.25 0.78 1000 K7
25 BU 1.25 0.78 100 coil
25 BU 1.25 0.78 1000 K7
25 YE/GN 1.25 0.78 100 coil
25 YE/GN 1.25 0.78 1000 K7
35 BK 1.75 0.554 50 coil
35 BK 1.75 0.554 500 K7
35 BU 1.75 0.554 50 coil
35 BU 1.75 0.554 500 K7
35 YE/GN 1.75 0.554 50 coil
35 YE/GN 1.75 0.554 500 K7
50 BK 2.50 0.386 50 coil
50 BK 2.50 0.386 500 K7
50 BU 2.50 0.386 50 coil
50 BU 2.50 0.386 500 K7
50 YE/GN 2.50 0.386 50 coil
50 YE/GN 2.50 0.386 500 K7
70 BK 3.50 0.272 50 coil
70 BK 3.50 0.272 250 K6
70 BU 3.50 0.272 50 coil
70 BU 3.50 0.272 250 K6
70 YE/GN 3.50 0.272 50 coil
70 YE/GN 3.50 0.272 250 K6
95 BK 4.75 0.206 250 K7
120 BK 6.00 0.161 250 K7
150 BK 7.50 0.129 250 K8
reko
Reka Product Support Service  Reka Cables maintain this Product Support Service for use of customers of Reka Cables Ltd and customers of Reka Corporation. From the Service customers can load and obtain in e-form product – and support material for Reka Products for their own business needs. Reka Product Support Service can be used by all customers, who approve these conditions.  The use of Reka® trade mark and the material obtainable from the Product Support Service is limited to the normal conduct of business of customers and to connection thereof, but provided that that the use will not defame the Reka® trade mark and is not in conflict with good business manners. The right of use of use is free of charges and valid until further notice.  The customer is not allowed to convey the material loaded or printed from Reka Product Support Service, except in normal connection to business for purposes such as planning, advertising and the like or as attached to such material. The origin of the material must be mentioned in connection thereof.  Reka® trade mark and the material obtainable in e-form from Reka Product Support Service, as well as the copyrights related thereof, are property of Reka Cables Ltd and in connection with copying or printing these rights will not be conveyed of transferred to the customer even in part. Reka Cables Ltd guarantees that these materials, which can be printed or loaded from the site, do not infringe immaterial rights of third parties.  Reka Cables Ltd reserves the right to close the Product Support Service without prior notice and reserves the right to limit or prevent the use of the Product Support Service by certain identified users without prior notice.  The pages of Reka Product Support Service can be used in the form as they appear at each occasion. Reka Cables Ltd has done its best to ensure that the information is correct and up-to-date, but it can nor be guaranteed that the pages could not contain unintended mistakes or out-of-date information. Reka Cables Ltd underlines that technical information and price information on the pages is not binding.  Reka Cables Ltd is not liable for damages, which may result in relation with mistakes or incorrect information on the pages or files of Reka Product Service, malfunction of the pages or with use of information obtainable from the pages without separately confirming from Reka Cables Ltd that the information used is correct and up-to-date.